Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
fire tube boiler with level
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
A fire-tube boiler is a type of boiler in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the …Get Price
This is done by creating a very light fire in the furnace, sufficient to speed up the evaporation but not to harm the refractory. Before starting the fire, fill the boiler to the normal level with treated, deaerated water. Leave a vent open to prevent pressure build up during the dry out period.Get Price
Aug 18, 2021 · Cochran boile r is a vertical, multi-tube boiler generally used for small capacity steam generation. The Cochran boiler is made in different sizes of evaporative capacities ranging from 150 to 3000 kg per hour and working pressure up to 15bar. The Cochran boiler consists of an external cylindrical shell and a firebox.Get Price
a. Boiler design/application – The boiler operator should know fire tube, vertical (submerged and nonsubmerged), horizontal, water tube, and cast iron type boiler construction. The boiler operator should be able to describe the differences between package and site-erected boilers.Get Price
fire in the fire box, when water level in the boiler comes down the limit and it prevents from blasting the boiler, melting the tube and over heating the fire-box crown plate. A fusible plug is shown in fig. It is located in water space of the boiler. The fusible metal is protected from direct contact of water by gun metal plug and copper plug.Get Price
Boiler steam drum water level is one of the most important power plant parameters to both measure and control. Control of the proper water level in the boiler is critical for safe operation of the boiler. If the level is too low, boiler tubes will be damaged by overheating. If theGet Price
750-94 (revised 2009) Model CB, CB-LE Packaged Boiler Manual i Model CB, CB-LE Packaged Boiler 750-94 Table of Contents CHAPTER 1 Basics of Firetube Operation 1-1 1.1 — Introduction 1-1 1.2 — The Boiler 1-4 1.3 — Construction 1-5 1.4 — Steam Controls (All Fuels) 1-6 1.4.1 — Operating Limit Pressure Control 1-6 1.4.2 — High Limit Pressure Control 1-7 1.4.3 — …Get Price
Feb 24, 2012 · Fire tube boiler is one of the most basic types of boiler and the design is also very old. It was popular in 18 th century. It was mainly used for steam locomotive engines. Operation of Fire Tube Boiler. Operation of fire tube boiler is as simple as its construction. In fire tube boiler, the fuel is burnt inside a furnace.The hot gases produced in the furnace then passes …Get Price
Sep 09, 2020 · Locomotive boiler is a boiler type that is used to heat up the water and create steam from this water. This boiler sits horizontally, just like Lancashire boiler and Cornish boiler. Many people think that Locomotive boiler is a water tube boiler, but in fact, it's a fire-tube boiler.Get Price
Fire Tube Boilers Sellers Fire tube boilers were originally designed to solve the problems that are inherent to the traditional scotch marine boiler design. All firetube boilers distribute energy through a collection of water-backed tubes to enable heat transfer. The Sellers Boiler is …Get Price
Fire Tube Boiler : Types Construction, Working - Thermodyne BoilersGet Price
Lancashire Boiler: Definition, Parts, Working Principle, Advantages, Application [Notes & PDF] Lancashire Boiler is a fire tube boiler. It was developed in 1844 by Sir William Fairbairn. It is a stationary-type boiler and works on the principle of a Heat exchanger. In this paper, we will study the definition, Construction, Working principle Get Price
Fire Tube Boiler Plant Water Wall In Boiler SA210C Steel High Low Pressure . Boiler Water Wall . Description. A waterwall in a boiler is any furnace wall that is comprised of refractory and tubes in a water-tube boiler. The tubes are evenly spaced and generally connect to headers which in turn are connected back to the main generating bank of Get Price
151,779. Todd, I. Jan. 22, 1920. Water-circulation, apparatus for promoting.- To promote the water-circulation in a fire-tube boiler, a circulating-pump a is placed inside the boiler near the normal water-level, and is so connected by a suction pipe b to the bottom of the water space that water is drawn upwards and discharged at or near the tops of the furnaces.Get Price
5. Boiler will trip if Deaerator low low level switch isBoiler will trip if Deaerator low low level switch is activatedactivated 6.6. Boiler will trip is ID fan trips Boiler will trip is ID fan trips 7 Boiler will trip if instrument air pressure fails 24/06/201024/06/2010 THERMODYNE TECHNOLOGIES PRIVATE LIMITEDLIMITED 23. Boiler will trip if Get Price
May 26, 2020 · Mobrey- Automatic Water Level ControllersFor smoke tube boilers, mobrey is fitted externally on the nozzles coming out of the steam boiler shell curvature. IGet Price
1. Fire tube boilers 2. Water tube boilers 1. Fire tube boilers : Fire-tube boiler is a type of boiler in which hot gases from a fire pass through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermalGet Price
Water tube boilers pass water through the boiler tubes, with the fire and hot combustion gases contacting the exterior of the tubes (see Figure 1.2). Water tube boilers are used in high-pressure and very-high-pressure applications. Most military installations have a central boiler plant containing water tube boilers in addition to fire tube Get Price
A fire-tube boiler is a type of boiler in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.. The fire-tube boiler developed as the third of the four major historical types of boilers: low …Get Price
Answer (1 of 3): Low pressure firetube boilers operating pressures are up to 15 psig. Higher pressure systems operate from 15psig to 350psig. Although firetube boilers are available in ratings up to 85,000 pounds of steam per hour(lb/hr), they are generally used when the steam pressure is under 1Get Price
Nov 18, 2020 · 3. Inspect fire side for soot or damage and water side for scale or corrosion & Clean the boiler inside and out. 4. Hydro test boiler for leaks (tube joints and piping). 5. Inspect all refractory for fallen broken chunks. 6. Check gas regulator pressure settings. 7. Replace or re-certify safety valves. 8. Bubble test fuel train safety shut-off Get Price
Clarification: The advantages of using a fire tube boiler are low first cost, reliability in operation, less draught required, quick response to load changes, etc. 3. Which of these is a type of fire-tube boiler? a) Externally fired b) Internally fired c) Internally & Externally fired d) None of the mentioned Answer: cGet Price
Nov 23, 2021 · 3pass gas fired boiler. Gas fire tube boiler body in the overall structure of the bottom furnace, smoke tube symmetrical arrangement. The drum is composed of φ1904×12 cylinder body and φ1900×14 front and rear tubesheet assembly. The backcombustion chamber is composed of φ1300×12 inner front and inner back tube plates and φ1296×16 Get Price
Getting started Biomass Pellet Fired Boiler Biomass Pellet Fired Boiler - China Factory, Suppliers, Manufacturers We're commitment to offer you the aggressive cost,superb products and solutions top quality, too as fast delivery for Biomass Pellet Fired Boiler, Cfb Biomass Steam Boiler, Pulverized Coal Boilers, Heavy Oil Boiler 5 Ton,Biomass Boiler Room.Get Price
A fire-tube boiler is a type of boiler in which hot gases from a fire pass through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam. Their advantage over boilers with a single large flue is Get Price
Jan 09, 2019 · In a fire tube boiler, hot gas passes through the pipes and boiler feed water is inside the shell to be converted into steam. Fire tube boilers are usually used for relatively small steam capacities with low to moderate steam pressures. As a guideline, competitive fire tube boilers for steam speeds up to 12,000 kg / hour with pressures up to 18 Get Price
Firebox—the area of a boiler where the burners are located and where radiant heat transfer occurs, p. 296. Fire tube boiler—a device that passes hot combustion gases through the tubes to heat water on the shell side, p. 298. Igniter—a device (similar to a spark plug) that automatically ignites the flammableGet Price
A locomotive boiler is a multi-tubular boiler and it has a horizontal drum axis. The circulation in the locomotive boiler is natural, also it is a medium pressure boiler, the draft is artificial, forced circulation, mobile, solid fuel fired fire tube boiler.Get Price
The only thing that allows a boiler to withstand these furnace temperatures is the presence of water in all tubes of the furnace at all times that a fire is present. Low-water conditions will literally melt steel boiler tubes with the result closely resembling a …Get Price
Jan 09, 2019 · In a fire tube boiler, hot gas passes through the pipes and boiler feed water is inside the shell to be converted into steam. Fire tube boilers are usually used for relatively small steam capacities with low to moderate steam pressures. As a guideline, competitive fire tube boilers for steam speeds up to 12,000 kg / hour with pressures up to 18 Get Price